*Terms and Conditions Applied:

  1. PRIMA will only measure combustion efficiency of single boiler and give report for FREE.
  2. If multiple boilers present at the company, except the first one all others will be chargeable.
  3. All Travelling and Lodging expenses to be born by the customer

*Terms and Conditions Applied:

  1. PRIMA will only measure combustion efficiency of single boiler and give report for FREE.
  2. If multiple boilers present at the company, except the first one all others will be chargeable.
  3. All Travelling and Lodging expenses to be born by the customer

"We are concerned about the most cherished dream in the world - LIFE" - Dr. Pritesh M. Shah

Home > products > In-Situ Oxygen Analyzer

PISO-19

PISO-19 Oxygen Analyzer is a new generation of In-situ Online monitoring instrument, which can monitor the Oxygen of Flue Gas in various typical application in a long time under severe conditions. It is very crucial parameter to calculate the combustion efficiency controller. 

PISO-19 Zirconia Oxygen sensor is equipped with blowback unit. compared with conventional integrated monitor, it can measure Oxygen with settable range from 0 to 50%. LCD display measure data and signals to controller. Smaller size ensures convenient moving, installation and maintenance.

Apply to Oxygen Measurement in industries of high energy consumption like Power, Ceramic and Steel. Glass industries having facilities of Furnace, Boilers, Hot Air Generator, Thermic Fluid heater etc...

Features...

In-situ method, hence directly to insert probe in flue gas duct.

Ultra-high-precision oxygen sensor achieves the measurement of accurate %.

Large LCD display to operating unit provides good interface.

 Timing back blow time.

Strengthen output signal protection.

Technical Specifications..

Environmental Temperature

0-60°C

Storage Humidity

0-85 % RH

Signal Output

1 x 4-20 mA, isolation (Optional)
1 x MODBUS RS485

Range Measurement

0 to 25% v, Resolution: 0.1%v

Suitable for Temperature (Flue
Gas)

0-600°C / 1000°C (customizable)

Suitable for Velocity

0 - 40 m/s

responce time

< 5s

Accuracy

± 2% at constant temperature

Material of Probe Tube inserted

316L steel, Probe length depends on Duct OD & ID.

purging

Auto Purge available

Calibration

Auto calibration with purge air.

Measurement Standards

Meets the measurement requirements of EN14181